I recently published tests showing that carbon actually removes VOCs. But adding that carbon layer raises a question: adding carbon means the fan has to power through yet another layer of resistance. Does that make purifier less effective at removing particulates?
Test Method
To test this question, I ran 10 room tests with the Cannon and 10 tests with the Original DIY in the same 15m2 Beijing apartment as my earlier tests without a carbon layer.
I measured how much particulate it removed with a Dylos particle counter and compared the particle counts (1) before I turned on the purifier at night and (2) the average of the last four hours before I woke up in the morning.
Carbon vs. HEPA Results
With the additional charcoal layer, the Cannon particulate effectiveness dropped 1-2%. Thus, charcoal has a very minor negative effect on the Cannon.
However, the Original DIY had a harder time powering through the extra layer. Its 0.5 micron effectiveness dropped 19%, and 2.5 micron effectiveness dropped 15%.
Conclusion: Carbon Tips
For people who need carbon (and that may not be everyone), I would recommend adding the carbon to the Cannon, but I would think twice about adding carbon to the Original. One workaround is to have one Original fan running with a HEPA and another running with a carbon filter.
As always, I’m posting the raw data and more details on the test for fellow nerds below.
Data: Cannon
The previous Cannon test data is in my earlier post. The raw data for the 10 new tests of the Cannon + carbon + HEPA are here:
Over the 10 testing days, outdoor air pollution went down significantly on 6 days–poor luck! To test whether that affected the overall estimate, I isolated the three testing days with changes in outdoor PM2.5 concentration of less than 10 micrograms.
For those three days, the 0.5 micron results were still 95%. The 2.5 micron results were 93%, which is 2% lower than in the overall tests. Thus, the overall estimate seems to be little affected by outdoor fluctuations when averaged over all of the tests.
Data: Original DIY
Below is the data for 10 tests with the Original DIY.
One day (12/21) was an outlier because the outdoor AQI almost tripled during the test. Thus, I calculated the average with and without that outlier removed. With the outlier included, .5 microns effectiveness was 5% lower and 2.5 micron effectiveness was 2% lower.