{"id":26787,"date":"2023-06-19T09:22:00","date_gmt":"2023-06-19T01:22:00","guid":{"rendered":"https:\/\/smartairfilters.com\/?p=26787"},"modified":"2023-06-15T21:22:37","modified_gmt":"2023-06-15T13:22:37","slug":"qp-air-quality-monitors-3rd-party-testes-top-accuracy-low-cost","status":"publish","type":"post","link":"https:\/\/smartairfilters.com\/en\/blog\/qp-air-quality-monitors-3rd-party-testes-top-accuracy-low-cost\/","title":{"rendered":"QP Air Quality Monitors: 3rd Party Tests show Top Accuracy and Low-Cost"},"content":{"rendered":"<p>The <a href=\"https:\/\/smartairfilters.com\/en\/product\/qp-lite-air-quality-monitor-qingping\/\">QP Lite<\/a> and <a href=\"https:\/\/smartairfilters.com\/en\/product\/qp-pro-air-quality-monitor-qingping\/\">QP Pro<\/a> are great pieces of kit that Smart Air has been <a href=\"http:\/\/smartairfilters.com\/shop\/\">selling<\/a> for the past year. Smart Air\u2019s own internal testing shows the devices were the most accurate we have ever tested. But how do they fair in third-party government tests?<\/p>\n\n\n\n<p>We sent them to the California Government\u2019s testing program: the <a href=\"https:\/\/www.aqmd.gov\/aq-spec\/evaluations\">South Coast AQMD<\/a> in the for further testing. The results of the test are truly impressive.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter\"><img decoding=\"async\" src=\"https:\/\/lh4.googleusercontent.com\/L4aZhmzcPqi5AyDsvUoKASHFlnzyicKNtdPKbf4QJy1UZCDPvmwbihSyHBBSR9JHzqVICVz6AJ2oKxWzbbP6HDEDkBtQ0sF5bix60ybGyxySCK9c3woruKwCxs9FJY_J4GGLZsR5re6DYt-CI5XtHQ\" alt=\"QP Pro Air Quality Monitors\" \/><\/figure><\/div>\n\n\n<h2 class=\"wp-block-heading\">QP Monitors Performance &#8211; Third-Party Tested<\/h2>\n\n\n\n<p>The QP Lite and QP Pro both earned a top 10 spot when compared to the 82 monitors tested by the AQMD. The QP Lite ranked 7<sup>th<\/sup> and the QP Pro 8th.&nbsp;<\/p>\n\n\n\n<p>AQMD observed a remarkable correlation between the reference devices and QP monitors, reaching an accuracy rate of 97%.<\/p>\n\n\n\n<p>Note: R2 is used as the measure of the accuracy of the monitors. R2 measures how much variance exists between the actual value of PM2.5 versus the calculated value by each monitor. An R2 of .7 is represented by an accuracy of 70% in this article.<\/p>\n\n\n\n<p><a href=\"https:\/\/smartairfilters.com\/en\/blog\/best-pm2-5-air-quality-monitors-2023\/?rel=1\">Read More: Best PM2.5 Air Quality Monitors in 2023<\/a><\/p>\n\n\n\n<p>The QP indoor monitors have the lowest mean absolute error (MAE) out of all tested. MAE is the average of the absolute difference between the monitor and the reference devices. Smaller MAE values mean lower measurement error. The QP monitors achieved the lowest measurement error of only 1.8\u00b5g\/m3 in the field test.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter\"><img decoding=\"async\" src=\"https:\/\/lh4.googleusercontent.com\/cpw8kjAWo3LGGfahdWpMlcaAhQvkeG5U-rLuuX9Iu1KgXt3FAAr6Z463I-rDJdH6lKeIbLDVH5rNOfRcmgFxyRKnl8TEjr25sDSUaQZL1nMyX5VORmLA-qVW8zT90-cZHTxG5X0lENfnaYRbpMrndg\" alt=\"QP lite Air Quality Monitors\" \/><\/figure><\/div>\n\n\n<h2 class=\"wp-block-heading\">PM2.5 Air Quality Monitors: Price \u2260 Accurate<\/h2>\n\n\n\n<p>The price range of these top 10 monitors varies from $70 to $2000. <a href=\"https:\/\/smartairfilters.com\/en\/blog\/expensive-air-quality-monitors-less-accurate-than-cheaper-competition\/\">Once proven again<\/a>, shown in the chart below, there was no correlation between price and accuracy. The more expensive PM2.5 monitors did not necessarily perform better. The 3 highest-performing air quality monitors were all priced under $200. <a href=\"https:\/\/smartairfilters.com\/en\/product\/qp-lite-air-quality-monitor-qingping\/\">QP Lite<\/a> is the second most affordable monitor among the top 10 list.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter\"><img decoding=\"async\" src=\"https:\/\/lh4.googleusercontent.com\/1Ccub7DHMgxqjG54lcc6uaEJBgNuV3uPprAObpn3DNYjCXYOMZisKXHJFUspV-QPoPneRCU-Xb7VAzUMdPzlJr-K0CQSRh_s5170AwGvh1hAl2lBu-871x_HF_Rs2tPaoVezvPpSKkjj47x9aLF2hQ\" alt=\"Air Quality Monitors price vs accuracy\" \/><\/figure><\/div>\n\n\n<p><a href=\"https:\/\/smartairfilters.com\/en\/blog\/expensive-air-quality-monitors-less-accurate-than-cheaper-competition\/\">Read more: Cheap Air Quality Monitors More Accurate Than Expensive Sensors<\/a><\/p>\n\n\n\n<p><\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Open Data<\/h4>\n\n\n\n<p>The South Coast AQMD performed the air quality monitor tests. The complete test data are openly available on their website. The table ranks monitors based on their field MAE values, lowest value means the least measurement error and highest accuracy in an alternative perspective.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td><strong>Rank<\/strong><\/td><td><strong>Monitors<\/strong><\/td><td><strong>Model<\/strong><\/td><td><strong>Price(USD)<\/strong><\/td><td><strong><\/strong><strong>Accuracy<\/strong><\/td><td><strong>*Field MAE (\u00b5g\/m3)<\/strong><\/td><\/tr><tr><td>1<\/td><td><img decoding=\"async\" src=\"https:\/\/lh4.googleusercontent.com\/PcHnVr5f3hTL2hclA4W9QMdZ0WTj7mKMhaUf6GaD04TzfFuoO6nMlhyqHQRShO98kqWfAAq1ZSAR4EWq8WXCWOPU__tc1HO61FBgz6Qevu5wes12KRQduk-y2sVPPtt7bhzFFoeZS0ZJyQ9hOBoNLA\" width=\"83\" height=\"83\"><\/td><td>QP Pro<\/td><td>$135<\/td><td>88%<\/td><td>1.8 to 2.3<\/td><\/tr><tr><td>2<\/td><td><img decoding=\"async\" src=\"https:\/\/lh3.googleusercontent.com\/x9cahHMowvmk0kjbM7JV6krWJ9LmjpWYxzduAWKMTeqvedig63kBwj-NxCULNt7wMwEWukCCFb1DsFHoTIztkjiTRFPTFiV-u60hD65h1LCfLzCT9hkeL7BJue6-SNak28nlnS1PgHB9CkgeNIHiYw\" width=\"83\" height=\"83\"><\/td><td>QP Lite<\/td><td>$96<\/td><td>89%<\/td><td>1.8 to 3.6<\/td><\/tr><tr><td>3<\/td><td><img decoding=\"async\" src=\"https:\/\/lh3.googleusercontent.com\/A9Odr2AyhhD7CIuUGohDGSDTX168ug5EzyPCSyfBU9QJj42FganGhmVFMqRAfKKnaThVi3Cto2YtzMaSsUTgqg16BeeWOWiNMPOKKa1gQYGBgBq3bqdF_9Gis3Ig8Uv613FsHcDs6wPXgrk3woZf5A\" width=\"83\" height=\"83\"><\/td><td>Elitech (Temtop LKC-1000S+)<\/td><td>$140<\/td><td>92%<\/td><td>3.1 to 3.6<\/td><\/tr><tr><td>4<\/td><td><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/lh6.googleusercontent.com\/Nm0jfDMpMf9sq_f03NkGbfxmXnWOJunpbjwlesZPqCY4lI0e5DfJAOrBrRPF9LZ6vGxHGB0hYrioCkyquw7webJnnd1HNng7G9YVd335ZH2saPcw-Md2KU_SCI6FgDqFcalr_EZdkJdBUnONOgOxEQ\" width=\"83\" height=\"71\"><\/td><td>Tera Sensor (NextPM)<\/td><td>$70<\/td><td>91%<\/td><td>3.9 to 5.6<\/td><\/tr><tr><td>5<\/td><td><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/lh5.googleusercontent.com\/TYt96QuCKngwEy3ekxQPZi0M1yi13YQUVNxVEQDo68QsBpTlnlNjtG5R0g5z9V-XTVAty-EjmxEwxEtt36HvS5O3cT5x-hKLuhDZOR_2uvMdsjmHiipFFquUdO3IJ63u-JH4DhQogFq6REqewJfEbw\" width=\"83\" height=\"124\"><\/td><td>Sensirion (Nubo) Discontinued<\/td><td>$2,000<\/td><td>91%<\/td><td>4.7 to 5.2<\/td><\/tr><tr><td>6<\/td><td><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/lh3.googleusercontent.com\/DoBxhKmpeQoY-Qv-h2pCaCV0hERXhUP7aIkXqJUaiHpwXJsGcA4Di_IRE3VLBzdiLUH-rEDeK1RRxeTzlZRwLRdWIYnwR_Euw4Ejgq3Wu270NY_WhpbrPsE8cQPuH1eEgAtBhtSD_GfvZvV5_Ud-3A\" width=\"83\" height=\"131\"><\/td><td>Atmotube (Pro)<\/td><td>$189<\/td><td>88%<\/td><td>4.9 to 5.9<\/td><\/tr><tr><td>7<\/td><td><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/lh4.googleusercontent.com\/g2uhtpqBhr2om-_zsmoXro4immb5Dyw07xMlcy2hwtyreqbpCYeE7jj6TLv7caEtHdNqW7plTcNCbExMdVZ-hhqNApZMQ_ILtoX_g1V3GxAy5nfdCtGFBxwigWUiHaxk63NAK8KX1NbRRlbiAqFXUg\" width=\"83\" height=\"124\"><\/td><td>Applied Particle Technology (MINIMA)<\/td><td>$995<\/td><td>88%<\/td><td>5.8 to 6.5<\/td><\/tr><tr><td>8<\/td><td><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/lh3.googleusercontent.com\/nzN0JZ62uXepnQTGUXOUESXh4hqYpaa2Mi3nG6fxuJNpU8fFsh79K2_U_pYFNDjFwrOpv1L-92j7LllkjiPmnH9hTrGArdCS86cNlsGVm1T7EJpiMHJ7NtV0RjYCvKn8rvt3J36EYLOgsQ9pPFfNLQ\" width=\"83\" height=\"124\"><\/td><td>Air Quality Egg (2022 Model)<\/td><td>$671<\/td><td>89%<\/td><td>6.0 to 7.1<\/td><\/tr><tr><td>9<\/td><td><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/lh3.googleusercontent.com\/1veIOhQxW9CUdjCIhB3P9AIjFgPehxjwxMtS33XWNiiQmHrL04GDkOVK0h3BuNNSTJVkvPs9uX7W_GGRNLH6afWLJwbVW-eOMJv7y-rzjk6erBkL5C3mCAKHOBky9JPUG1A9Nr4ZRvqIoJbBiPffjQ\" width=\"83\" height=\"83\"><\/td><td>PurpleAir (PA-II)<\/td><td>$200<\/td><td>95%<\/td><td>N\/A<\/td><\/tr><tr><td>10<\/td><td><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/lh5.googleusercontent.com\/AenLVtuYWVcJgh5Oe2TRiHfQ04igsPZdU7dWjLtavjfzcn0kxjPYB5xl-0zHD5AkEqepeGDIhvMYKHAK6U20fZUPJiLkO-9lOUQbD7mXPHxJieZyOr0a6MH0pdbsxSbZAKhkGGw5tEHj7k5LwU-7Xw\" width=\"83\" height=\"124\"><\/td><td>PurpleAir (PA-I)<\/td><td>$150<\/td><td>91%<\/td><td>N\/A<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter\"><img decoding=\"async\" src=\"https:\/\/lh3.googleusercontent.com\/3eeTaR_8ijXh8cVcsyRiwki8hrtZ8WD9ILHKXOgKL_2wLYCG1uLdU4RRGtR9DIwwcVIY4MkuLBQx5ZWyQ9ZBDiikz3hRiITnQDIE8PTJi-2d7prunNSHbBmCmb9n5_-ZKoxOyz-Kuj9L-tNj_JNf2Q\" alt=\"QP Pro Air Quality Monitors\" \/><\/figure><\/div>\n\n\n<p><a href=\"https:\/\/smartairfilters.com\/en\/blog\/how-accurate-are-qingping-qp-pm2-5-air-quality-monitors\/\">Read More: Qingping Air Quality Monitor Review: Pro and Lite Models [2022]<\/a><\/p>","protected":false},"excerpt":{"rendered":"<p>The QP Lite and QP Pro are great pieces of kit that Smart Air has been selling for the past year. Smart Air\u2019s own internal testing shows the devices were the most accurate we have ever tested. But how do they fair in third-party government tests? We sent them to &#8230; <\/p>\n<p class=\"read-more-container\"><a title=\"QP Air Quality Monitors: 3rd Party Tests show Top Accuracy and Low-Cost\" class=\"read-more button\" href=\"https:\/\/smartairfilters.com\/en\/blog\/qp-air-quality-monitors-3rd-party-testes-top-accuracy-low-cost\/#more-26787\" aria-label=\"Read more about QP Air Quality Monitors: 3rd Party Tests show Top Accuracy and Low-Cost\">Read more<\/a><\/p>\n","protected":false},"author":10915,"featured_media":26789,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_relevanssi_hide_post":"","_relevanssi_hide_content":"","_relevanssi_pin_for_all":"","_relevanssi_pin_keywords":"","_relevanssi_unpin_keywords":"","_relevanssi_related_keywords":"","_relevanssi_related_include_ids":"","_relevanssi_related_exclude_ids":"","_relevanssi_related_no_append":"","_relevanssi_related_not_related":"","_relevanssi_related_posts":"","_relevanssi_noindex_reason":"","footnotes":""},"categories":[169,264,847,848],"tags":[889,890],"class_list":["post-26787","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-air-quality-monitors","category-indoor-air","category-qp-monitors","category-qp-monitors-air-quality-monitors","tag-air-quality-monitors","tag-qp-monitors","resize-featured-image"],"acf":[],"_links":{"self":[{"href":"https:\/\/smartairfilters.com\/en\/wp-json\/wp\/v2\/posts\/26787","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/smartairfilters.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/smartairfilters.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/smartairfilters.com\/en\/wp-json\/wp\/v2\/users\/10915"}],"replies":[{"embeddable":true,"href":"https:\/\/smartairfilters.com\/en\/wp-json\/wp\/v2\/comments?post=26787"}],"version-history":[{"count":1,"href":"https:\/\/smartairfilters.com\/en\/wp-json\/wp\/v2\/posts\/26787\/revisions"}],"predecessor-version":[{"id":26788,"href":"https:\/\/smartairfilters.com\/en\/wp-json\/wp\/v2\/posts\/26787\/revisions\/26788"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/smartairfilters.com\/en\/wp-json\/wp\/v2\/media\/26789"}],"wp:attachment":[{"href":"https:\/\/smartairfilters.com\/en\/wp-json\/wp\/v2\/media?parent=26787"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/smartairfilters.com\/en\/wp-json\/wp\/v2\/categories?post=26787"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/smartairfilters.com\/en\/wp-json\/wp\/v2\/tags?post=26787"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}