{"id":30260,"date":"2024-03-29T15:29:12","date_gmt":"2024-03-29T07:29:12","guid":{"rendered":"https:\/\/smartairfilters.com\/?p=30260"},"modified":"2024-05-29T13:55:29","modified_gmt":"2024-05-29T05:55:29","slug":"are-low-cost-ozone-monitors-effective","status":"publish","type":"post","link":"https:\/\/smartairfilters.com\/en\/blog\/are-low-cost-ozone-monitors-effective\/","title":{"rendered":"Are Low-Cost Ozone Monitors Effective?"},"content":{"rendered":"<p>Ozone detectors often come with a hefty price tag. Some start at US$4,000. This high cost prompts many people to search for more affordable ozone sensors. We&#8217;ve seen low-cost ozone monitors for sale priced at around US$100. Are they accurate?<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1211\" height=\"733\" src=\"https:\/\/smartairfilters.com\/wordpress\/wp-content\/uploads\/2024\/04\/image-1.png\" alt=\"ozone monitors on amazon\" class=\"wp-image-30263\" srcset=\"https:\/\/smartairfilters.com\/wordpress\/wp-content\/uploads\/2024\/04\/image-1.png 1211w, https:\/\/smartairfilters.com\/wordpress\/wp-content\/uploads\/2024\/04\/image-1-600x363.png 600w, https:\/\/smartairfilters.com\/wordpress\/wp-content\/uploads\/2024\/04\/image-1-1024x620.png 1024w, https:\/\/smartairfilters.com\/wordpress\/wp-content\/uploads\/2024\/04\/image-1-300x182.png 300w, https:\/\/smartairfilters.com\/wordpress\/wp-content\/uploads\/2024\/04\/image-1-768x465.png 768w\" sizes=\"(max-width: 1211px) 100vw, 1211px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Putting Cheap Ozone Sensors to the Test<\/h3>\n\n\n\n<p><a href=\"https:\/\/repository.library.noaa.gov\/view\/noaa\/59397\">Researchers at the University of Colorado<\/a> analyzed ozone levels generated by UVC light. They compared the accuracy of three different ozone monitors from China and compared them to the research-grade UV absorption Thermo Scientific Model 49i Ozone Analyzer.<\/p>\n\n\n\n<p>The three handheld ozone monitors tested were Shandong Renka, Shenzhen Dienmern, and Shenzhen YuanTe. These monitors range from US$55 to US$815.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-accent-color has-text-color has-link-color\"><tbody><tr><td><strong>Monitor<\/strong><\/td><td><strong>Company<\/strong><\/td><td><strong>Price<\/strong><\/td><td><strong>Model<\/strong><\/td><\/tr><tr><td><img decoding=\"async\" src=\"https:\/\/lh7-us.googleusercontent.com\/GH5JE5Weeeusb0QTXi2N70dyEADk0tSWHzoYklw2SPET9BclMxAoMuQeVYRolPLRIlmWYMv7zqo7LGh-amVayqnJ5StV09GodxeJTVLt2bAGvfy1fYZCDAMRpCZEYo8Iw-hcU9wE_j5jb4Xt4KBIX84\" width=\"76\" height=\"75\"><\/td><td>Shenzhen DienmernTesting Technology Co.,Ltd<\/td><td>$55<\/td><td>Model: DM509-O3Electrochemical sensor<\/td><\/tr><tr><td><img decoding=\"async\" src=\"https:\/\/lh7-us.googleusercontent.com\/hnKUg0AZjNcWvh2VVj8Mbv-v_oPjBLb8_twdQwlAvDngKGkRg0VDarC0xsZKJKHmpdQYQ4lANktx5L9ZnJHJm8Lx_aUTAr3P803ZDx7FqU78741dqBbfmBVGYc0Ss0fPvjsGHhl_-pHCUIrH9TxNjys\" width=\"76\" height=\"76\"><\/td><td>Shandong Renke ControlTechnology Co., Ltd.<\/td><td>$114<\/td><td>Model: RS-MG41-O3Electrochemical sensor<\/td><\/tr><tr><td><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/lh7-us.googleusercontent.com\/O7kgZgjRA6U6jQIXneKVL2YoTUMvkJeZ2tW_VuXR2pJZNviN8Dgsp3p3qDZw_fLvIB2aEmBRfyh8qlFG2YRWpQ7NcNpEw_5PASjcNeCrgd3S-kFhQf9hsKqgWbYwIZJPsqfXgc9Lmr2qDDlooe_xZs0\" width=\"76\" height=\"76\"><\/td><td>Shenzhen YuanTeTechnology Co., Ltd<\/td><td>$815<\/td><td>Model: SKY2000Electrochemical sensor<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p>Researchers released ozone into a chamber and thoroughly mixed it with a fan to ensure it was evenly distributed around the chamber. While the Thermo Ozone Analyzer continuously logged the ozone levels, researchers manually read and recorded the readings from the handheld ozone monitors.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><a href=\"https:\/\/repository.library.noaa.gov\/view\/noaa\/59397\"><img loading=\"lazy\" decoding=\"async\" width=\"771\" height=\"1032\" src=\"https:\/\/smartairfilters.com\/wordpress\/wp-content\/uploads\/2024\/04\/image.png\" alt=\"ozone monitors in tests\" class=\"wp-image-30262\" style=\"width:auto;height:600px\" srcset=\"https:\/\/smartairfilters.com\/wordpress\/wp-content\/uploads\/2024\/04\/image.png 771w, https:\/\/smartairfilters.com\/wordpress\/wp-content\/uploads\/2024\/04\/image-448x600.png 448w, https:\/\/smartairfilters.com\/wordpress\/wp-content\/uploads\/2024\/04\/image-765x1024.png 765w, https:\/\/smartairfilters.com\/wordpress\/wp-content\/uploads\/2024\/04\/image-224x300.png 224w, https:\/\/smartairfilters.com\/wordpress\/wp-content\/uploads\/2024\/04\/image-768x1028.png 768w, https:\/\/smartairfilters.com\/wordpress\/wp-content\/uploads\/2024\/04\/image-600x803.png 600w\" sizes=\"(max-width: 771px) 100vw, 771px\" \/><\/a><figcaption class=\"wp-element-caption\">Source:&nbsp;Environmental Science &amp; Technology Letters, 10(8), 668-674<\/figcaption><\/figure><\/div>\n\n\n<h3 class=\"wp-block-heading\">Are Cheap Ozone Sensors Accurate?<\/h3>\n\n\n\n<p>The tests found that these sensors were inadequate when measuring ozone levels below 200 parts per billion (PPB). None of the sensors were responsive to ozone levels below 100 PPB. Only the Shenzhen YuanTe monitor showed good accuracy when measuring ozone levels above 200 PPB. The other two models consistently underperformed. It&#8217;s worth noting that the Shenzhen YuanTe monitor is 10 times more expensive than the cheapest model.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"960\" height=\"540\" src=\"https:\/\/smartairfilters.com\/wordpress\/wp-content\/uploads\/2024\/03\/Ozone-monitors.jpg\" alt=\"none of the sensors were responsive to ozone levels below 100 PPB\" class=\"wp-image-30278\" srcset=\"https:\/\/smartairfilters.com\/wordpress\/wp-content\/uploads\/2024\/03\/Ozone-monitors.jpg 960w, https:\/\/smartairfilters.com\/wordpress\/wp-content\/uploads\/2024\/03\/Ozone-monitors-600x338.jpg 600w, https:\/\/smartairfilters.com\/wordpress\/wp-content\/uploads\/2024\/03\/Ozone-monitors-300x169.jpg 300w, https:\/\/smartairfilters.com\/wordpress\/wp-content\/uploads\/2024\/03\/Ozone-monitors-768x432.jpg 768w\" sizes=\"(max-width: 960px) 100vw, 960px\" \/><figcaption class=\"wp-element-caption\">Source:&nbsp;Environmental Science &amp; Technology Letters, 10(8), 668-674<\/figcaption><\/figure>\n\n\n\n<p>The WHO\u2019s limit for ozone is 100 micrograms per meter cubed (\u00b5g\/m\u00b3) for an 8-hour average, which equates to 100 PPB. This means that the ozone monitors are not able to effectively detect ozone problems in normal environments.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"960\" height=\"540\" src=\"https:\/\/smartairfilters.com\/wordpress\/wp-content\/uploads\/2024\/03\/Ozone-monitors-1.jpg\" alt=\"Only Shenzhen YuanTe monitor showed good accuracy \" class=\"wp-image-30277\" srcset=\"https:\/\/smartairfilters.com\/wordpress\/wp-content\/uploads\/2024\/03\/Ozone-monitors-1.jpg 960w, https:\/\/smartairfilters.com\/wordpress\/wp-content\/uploads\/2024\/03\/Ozone-monitors-1-600x338.jpg 600w, https:\/\/smartairfilters.com\/wordpress\/wp-content\/uploads\/2024\/03\/Ozone-monitors-1-300x169.jpg 300w, https:\/\/smartairfilters.com\/wordpress\/wp-content\/uploads\/2024\/03\/Ozone-monitors-1-768x432.jpg 768w\" sizes=\"(max-width: 960px) 100vw, 960px\" \/><figcaption class=\"wp-element-caption\">Source:&nbsp;Environmental Science &amp; Technology Letters, 10(8), 668-674<\/figcaption><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">How about Using Affordable Ozone Monitors Outdoors?<\/h3>\n\n\n\n<p>In Shanghai, the average outdoor ozone levels ranged between 100-200 PPB throughout the year. That means these portable ozone monitors cannot provide accurate outdoor measurements.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1478\" height=\"936\" src=\"https:\/\/smartairfilters.com\/wordpress\/wp-content\/uploads\/2024\/04\/Shanghai-Average-Ozone-EN.png\" alt=\"Shanghai ozone levels\" class=\"wp-image-30275\" style=\"width:1000px;height:auto\" srcset=\"https:\/\/smartairfilters.com\/wordpress\/wp-content\/uploads\/2024\/04\/Shanghai-Average-Ozone-EN.png 1478w, https:\/\/smartairfilters.com\/wordpress\/wp-content\/uploads\/2024\/04\/Shanghai-Average-Ozone-EN-600x380.png 600w, https:\/\/smartairfilters.com\/wordpress\/wp-content\/uploads\/2024\/04\/Shanghai-Average-Ozone-EN-1024x648.png 1024w, https:\/\/smartairfilters.com\/wordpress\/wp-content\/uploads\/2024\/04\/Shanghai-Average-Ozone-EN-300x190.png 300w, https:\/\/smartairfilters.com\/wordpress\/wp-content\/uploads\/2024\/04\/Shanghai-Average-Ozone-EN-768x486.png 768w\" sizes=\"(max-width: 1478px) 100vw, 1478px\" \/><\/figure>\n\n\n\n<p>Read more: <a href=\"https:\/\/smartairfilters.com\/en\/blog\/analysis-shows-ozone-levels-rising-across-china\/\">Ozone Pollution: Often Invisible, Always Dangerous<\/a><\/p>\n\n\n\n<h3 class=\"wp-block-heading\">The Technologies Behind Ozone Monitors<\/h3>\n\n\n\n<p>Traditional, expensive ozone monitors use UV absorption technology, but they tend to be bulky, expensive, and power-intensive. Two more user-friendly technologies to detect ozone are electrochemical sensors and heated metal oxide sensors (HMOS). Unlike conventional ozone monitors, electrochemical ozone sensors are more compact. However, the test results suggest that these inexpensive electrochemical ozone sensors do not deliver the performance and accuracy they claim, which could give users a false sense of safety.<\/p>\n\n\n<div class='bottom-line'><div class='bottom-line-top'>Bottom Line<\/div><div class='bottom-line-title'>Bottom Line: Are Low-Cost Ozone Monitors Effective?<\/div><div class='bottom-line-content'>\nAll three tested models failed accuracy tests, exposing reliability issues with low-cost ozone monitors. While they may appear to be a convenient portable solution, they lack precision in measuring ozone levels below 200 PPB, which is the most common use case.\n<\/div><div class='bottom-line-last'>Smart Air<\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>Ozone detectors often come with a hefty price tag. Some start at US$4,000. This high cost prompts many people to search for more affordable ozone sensors. We&#8217;ve seen low-cost ozone monitors for sale priced at around US$100. Are they accurate? Putting Cheap Ozone Sensors to the Test Researchers at the &#8230; <\/p>\n<p class=\"read-more-container\"><a title=\"Are Low-Cost Ozone Monitors Effective?\" class=\"read-more button\" href=\"https:\/\/smartairfilters.com\/en\/blog\/are-low-cost-ozone-monitors-effective\/#more-30260\" aria-label=\"Read more about Are Low-Cost Ozone Monitors Effective?\">Read more<\/a><\/p>\n","protected":false},"author":10915,"featured_media":30266,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_relevanssi_hide_post":"","_relevanssi_hide_content":"","_relevanssi_pin_for_all":"","_relevanssi_pin_keywords":"","_relevanssi_unpin_keywords":"","_relevanssi_related_keywords":"","_relevanssi_related_include_ids":"","_relevanssi_related_exclude_ids":"","_relevanssi_related_no_append":"","_relevanssi_related_not_related":"","_relevanssi_related_posts":"22463,12107,12183,7008,682,7928","_relevanssi_noindex_reason":"","footnotes":""},"categories":[17,169,599],"tags":[272,278,889,956],"class_list":["post-30260","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-air-pollution","category-air-quality-monitors","category-ozone","tag-air-pollution","tag-air-quality","tag-air-quality-monitors","tag-ozone-monitor","resize-featured-image"],"acf":[],"_links":{"self":[{"href":"https:\/\/smartairfilters.com\/en\/wp-json\/wp\/v2\/posts\/30260","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/smartairfilters.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/smartairfilters.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/smartairfilters.com\/en\/wp-json\/wp\/v2\/users\/10915"}],"replies":[{"embeddable":true,"href":"https:\/\/smartairfilters.com\/en\/wp-json\/wp\/v2\/comments?post=30260"}],"version-history":[{"count":7,"href":"https:\/\/smartairfilters.com\/en\/wp-json\/wp\/v2\/posts\/30260\/revisions"}],"predecessor-version":[{"id":30282,"href":"https:\/\/smartairfilters.com\/en\/wp-json\/wp\/v2\/posts\/30260\/revisions\/30282"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/smartairfilters.com\/en\/wp-json\/wp\/v2\/media\/30266"}],"wp:attachment":[{"href":"https:\/\/smartairfilters.com\/en\/wp-json\/wp\/v2\/media?parent=30260"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/smartairfilters.com\/en\/wp-json\/wp\/v2\/categories?post=30260"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/smartairfilters.com\/en\/wp-json\/wp\/v2\/tags?post=30260"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}